non-conductive ladder system: telescoping aluminium stepladder and lean-to ladder |
|
|
It's a unique tool |
|
|
|
|
Electrical Resistance 1000 Volts a.c. |
|
|
It comes in 4 models: |
||||||||||||
|
4 x 3 rungs, 4 x 4 rungs, 4 x 5 rungs, 4 x 6 rungs |
||||||||||||
| Since the appliances of insulating ladders in electrical ambients are safety critical, SKYLAX would strongly suggest preoperative tests. Tests shall be made before starting work each day, each time during the day when a higher voltage is going to be worked, and when changed conditions indicate a need for additional tests. A microammeter designed for use with insulating ladders shall be used for testing the dielectric current through the ladder legs with all legs bonded together at the metering point. If the measured dielectric current after 1 minute is less than 0,333 microampere for each kilovolt of nominal phase-to-phase voltage, the insulating ladder may be placed and the work started. A written record of these tests shall be maintained both with the equipment and in the responsible operating office. | ||||||||||||
|
|
||||||||||||
|
CountryStar |
||||||||||||
|
non-conductive telescoping aluminium lean-to ladder |
||||||||||||
|
for universal appliances |
||||||||||||
|
||||||||||||
|
Electrical Resistance 1000 Volts a.c. |
||||||||||||
|
It comes in 4 models |
||||||||||||
|
||||||||||||
| Since the appliances of insulating ladders in electrical ambients are safety critical, SKYLAX would strongly suggest preoperative tests. Tests shall be made before starting work each day, each time during the day when a higher voltage is going to be worked, and when changed conditions indicate a need for additional tests. A microammeter designed for use with insulating ladders shall be used for testing the dielectric current through the ladder legs with all legs bonded together at the metering point. If the measured dielectric current after 1 minute is less than 0,333 microampere for each kilovolt of nominal phase-to-phase voltage, the insulating ladder may be placed and the work started. A written record of these tests shall be maintained both with the equipment and in the responsible operating office. | ||||||||||||
| CityStar + CountryStar | JumboStep |
|
JumboStar |
Other
Ladders |
| KingStar |
Prices |
| ESD Stairs |
Contact |
| Cone
Hinges |
DEUTSCH |